Human CX43 (Connexin 43) ELISA Kit

Human CX43 (Connexin 43) ELISA Kit

Cat: EH25631
Assay Range: 0.15-10ng/mL
Sensitivity: 0.07ng/mL
Size: 96T Price: $520
Size: 48T Price: $416
Category: ELISA Kits Tags: ,

KEY FEATURES

Full NameConnexin 43
SynonymODDD; GJAL; GJA1; GJ-A1; Gap junction 43 kDa heart protein; Gap Junction Protein Alpha 1; Oculodentodigital Dysplasia; Syndactyly Type III
Assay TypeSandwich
ReactivityHuman
Range0.15-10ng/mL
Sensitivity0.07ng/mL
Sample TypeSerum,plasma and other biological fluids
Sample Volume100μL
Detection WavelengthOD450
Transportation Temperature2-8°C
SpecificityThe kit detected Human CX43 in the samples and no significant cross-species reactions were found
Microplate96-wells plate breakable into 12 x 8 wells strip

TEST PRINCIPLE

This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human CX43. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CX43 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CX43, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human CX43. You can calculate the concentration of Human CX43 in the samples by comparing the OD of the samples to the standard curve.

ELISA KIT COMPONENTS

Upon receipt, unpack promptly and store as recommended in the instructions.

ComponentsSpecificationsStorage and Notes
Micro Plate
96T: 8 wells×12 strips
48T: 8 wells×6 strips
Unopened: -20°C, 12 months
Unused: Put it back in the aluminum foil bag and seal it, store it at -20°C.
Reference Standard
96T: 2 vials
48T: 1 vial
Unopened: -20°C, 12 months
Please use freshly dissolved standards for each experiment. Discard any unused standards after dissolution.
Biotinylated Detection Ab Concentrate (100×)
96T: 120μL×1 vial
48T: 60μL×1 vial
Unopened: -20°C, 12 months
Unused: Please seal the concentrate and store it at -20°C, and discard the working solution.
HRP Conjugate Concentrate (100×)
96T: 120μL×1 vial
48T: 60μL×1 vial
Unopened: -20°C(Protect from light), 12 months
Unused: Please seal the concentrate and store it at -20°C, and discard the working solution.
Biotinylated Detection Ab Diluent
14mL×1
2-8℃, 12 months
HRP Conjugate Diluent
14mL×1
2-8℃, 12 months
Reference Standard & Sample Diluent20mL×1
2-8℃, 12 months
Washing Buffer Concentrate (25×)30mL×1
2-8℃, 12 months
Substrate Reagent(TMB)10mL×12-8°C(Protect from light),12 months
Stop Solution7mL×12-8°C/Room temperature

ASSAY PROCEDURES

TYPICAL DATA

 Standard Curve Image

Human CX43 ELISA Standard Curve

Typical data are for reference only and curves should be replotted for each experiment. The Logistics function is recommended for fitting.

PRECISION

Intra-Assay Precision (Precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays): Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components.

Intra-assay PrecisionInter-assay Precision
Sample123123
n202020202020
Mean (ng/mL)0.461.473.850.481.424.21
Standard deviation0.020.070.190.030.060.14
CV(%)5.354.594.846.494.043.23

RECOVERY

The recovery of Human CX43 spiked to three different levels in samples throughout the range of the assay in various matrices was evaluated.

Sample TypeRange (%)Average Recovery (%)
Serum(n=8)94-107101
EDTA plasma (n=8)92-10999
Cell culture media (n=8)84-9991

LINEARITY

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of Human CX43 in various matrices were diluted with the Reference Standard & Sample Diluent to produce samples with values within the dynamic range of the assay.

Pathways associated with GJA1 ELISA Kit

Arrhythmogenic Right Ventricular Cardiomyopathy Pathway Arrhythmogenic Right Ventricular Cardiomyopathy Pathway
Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) Pathway Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) Pathway
Calcium Regulation In The Cardiac Cell Pathway Calcium Regulation In The Cardiac Cell Pathway
EGFR1 Signaling Pathway EGFR1 Signaling Pathway
Formation Of Annular Gap Junctions Pathway Formation Of Annular Gap Junctions Pathway
Gap Junction Pathway Gap Junction Pathway
Gap Junction Assembly Pathway Gap Junction Assembly Pathway
Gap Junction Degradation Pathway Gap Junction Degradation Pathway
   💬 WhatsApp