KEY FEATURES
| Full Name | Glutathione S Transferase Mu 1 |
|---|---|
| Synonym | GST-M1; GST1; GSTM1-1; GSTM1a-1a; GSTM1b-1b; GTH4; GTM1; H-B; MU1; GST HB subunit 4 |
| Assay Type | Sandwich |
| Reactivity | Human |
| Range | 3.12-200ng/mL |
| Sensitivity | 1.17ng/mL |
| Sample Type | Serum,plasma and other biological fluids |
| Sample Volume | 100μL |
| Detection Wavelength | OD450 |
| Transportation Temperature | 2-8°C |
| Specificity | The kit detected Human GSTM1 in the samples and no significant cross-species reactions were found |
| Microplate | 96-wells plate breakable into 12 x 8 wells strip |
TEST PRINCIPLE
| This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human GSTM1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GSTM1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GSTM1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human GSTM1. You can calculate the concentration of Human GSTM1 in the samples by comparing the OD of the samples to the standard curve. |
ELISA KIT COMPONENTS
Upon receipt, unpack promptly and store as recommended in the instructions.
| Components | Specifications | Storage and Notes |
|---|---|---|
| Micro Plate | 96T: 8 wells×12 strips 48T: 8 wells×6 strips | Unopened: -20°C, 12 months Unused: Put it back in the aluminum foil bag and seal it, store it at -20°C. |
| Reference Standard | 96T: 2 vials 48T: 1 vial | Unopened: -20°C, 12 months Please use freshly dissolved standards for each experiment. Discard any unused standards after dissolution. |
| Biotinylated Detection Ab Concentrate (100×) | 96T: 120μL×1 vial 48T: 60μL×1 vial | Unopened: -20°C, 12 months Unused: Please seal the concentrate and store it at -20°C, and discard the working solution. |
| HRP Conjugate Concentrate (100×) | 96T: 120μL×1 vial 48T: 60μL×1 vial | Unopened: -20°C(Protect from light), 12 months Unused: Please seal the concentrate and store it at -20°C, and discard the working solution. |
| Biotinylated Detection Ab Diluent | 14mL×1 | 2-8℃, 12 months |
| HRP Conjugate Diluent | 14mL×1 | 2-8℃, 12 months |
| Reference Standard & Sample Diluent | 20mL×1 | 2-8℃, 12 months |
| Washing Buffer Concentrate (25×) | 30mL×1 | 2-8℃, 12 months |
| Substrate Reagent(TMB) | 10mL×1 | 2-8°C(Protect from light),12 months |
| Stop Solution | 7mL×1 | 2-8°C/Room temperature |
ASSAY PROCEDURES

TYPICAL DATA

Human GSTM1 ELISA Standard Curve
Typical data are for reference only and curves should be replotted for each experiment. The Logistics function is recommended for fitting.
PRECISION
Intra-Assay Precision (Precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays): Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean (ng/mL) | 9.72 | 26.35 | 71.63 | 9.48 | 24.16 | 67.75 |
| Standard deviation | 0.61 | 1.2 | 3.56 | 0.65 | 1 | 2.69 |
| CV(%) | 6.26 | 4.55 | 4.97 | 6.9 | 4.14 | 3.97 |
RECOVERY
The recovery of Human GSTM1 spiked to three different levels in samples throughout the range of the assay in various matrices was evaluated.
| Sample Type | Range (%) | Average Recovery (%) |
|---|---|---|
| Serum(n=8) | 85-98 | 91 |
| EDTA plasma (n=8) | 91-105 | 98 |
| Cell culture media (n=8) | 87-98 | 92 |
LINEARITY
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of Human GSTM1 in various matrices were diluted with the Reference Standard & Sample Diluent to produce samples with values within the dynamic range of the assay.

Products associated with GSTm1 ELISA Kits
| CYP1A1 ELISA Kit | publications with GSTm1 and CYP1A1 |
| CYP2E1 ELISA Kit | publications with GSTm1 and CYP2E1 |
| EPHX1 ELISA Kit | publications with GSTm1 and EPHX1 |
| CYP1B1 ELISA Kit | publications with GSTm1 and CYP1B1 |
| CYP3A4 ELISA Kit | publications with GSTm1 and CYP3A4 |
| GSTM2 ELISA Kit | publications with GSTm1 and GSTM2 |
| CYP2C19 ELISA Kit | publications with GSTm1 and CYP2C19 |
| CYP2B6 ELISA Kit | publications with GSTm1 and CYP2B6 |
| MAP3K5 ELISA Kit | publications with GSTm1 and MAP3K5 |
Pathways associated with GSTm1 ELISA Kit
| Aflatoxin B1 Metabolism Pathway | Aflatoxin B1 Metabolism Pathway |
| Biological Oxidations Pathway | Biological Oxidations Pathway |
| C-MYB Transcription Factor Network Pathway | C-MYB Transcription Factor Network Pathway |
| Chemical Carcinogenesis Pathway | Chemical Carcinogenesis Pathway |
| Defective AHCY Causes Hypermethioninemia With S-adenosylhomocysteine Hydrolase Deficiency (HMAHCHD) Pathway | Defective AHCY Causes Hypermethioninemia With S-adenosylhomocysteine Hydrolase Deficiency (HMAHCHD) Pathway |
| Defective GCLC Causes Hemolytic Anemia Due To Gamma-glutamylcysteine Synthetase Deficiency (HAGGSD) Pathway | Defective GCLC Causes Hemolytic Anemia Due To Gamma-glutamylcysteine Synthetase Deficiency (HAGGSD) Pathway |
| Defective GGT1 Causes Glutathionuria (GLUTH) Pathway | Defective GGT1 Causes Glutathionuria (GLUTH) Pathway |
| Defective GSS Causes Glutathione Synthetase Deficiency (GSS Deficiency) Pathway | Defective GSS Causes Glutathione Synthetase Deficiency (GSS Deficiency) Pathway |
| Defective MAT1A Causes Methionine Adenosyltransferase Deficiency (MATD) Pathway | Defective MAT1A Causes Methionine Adenosyltransferase Deficiency (MATD) Pathway |
Diseases associated with GSTm1 ELISA Kit
| Disease Susceptibility | publications with GSTm1 and Disease Susceptibility |
| Lung Neoplasms | publications with GSTm1 and Lung Neoplasms |
| Carcinoma, Squamous Cell | publications with GSTm1 and Carcinoma, Squamous Cell |
| Skin Diseases | publications with GSTm1 and Skin Diseases |
| Colorectal Neoplasms | publications with GSTm1 and Colorectal Neoplasms |
| Leukemia | publications with GSTm1 and Leukemia |
| Liver Diseases | publications with GSTm1 and Liver Diseases |
| Urinary Bladder Neoplasms | publications with GSTm1 and Urinary Bladder Neoplasms |
| Chromosome Aberrations | publications with GSTm1 and Chromosome Aberrations |
| Asthma | publications with GSTm1 and Asthma |
Organs/Tissues associated with GSTm1 ELISA Kit
| Lung | publications with GSTm1 and Lung |
| Liver | publications with GSTm1 and Liver |
| Bladder | publications with GSTm1 and Bladder |
| Stomach | publications with GSTm1 and Stomach |
| Prostate | publications with GSTm1 and Prostate |
| Kidney | publications with GSTm1 and Kidney |
| Brain | publications with GSTm1 and Brain |
| Heart | publications with GSTm1 and Heart |
| Bone | publications with GSTm1 and Bone |
| Eye | publications with GSTm1 and Eye |